A collage of four photos showing Clean Energy Credit Union members with their clean energy investments. Top left: a family with two young children smiles in front of a solar panel installation on a farm. Top right: a couple takes a selfie in front of two electric vehicles, including a red Rivian with its hood open. Bottom left: a person stands in front of a stone building with a large rooftop solar array and an HVAC unit. Bottom right: a person smiles and points proudly at their home energy meter.

Eligible Products and Services

What We Can Finance

Heat pumps, solar, windows, and more. See what’s eligible for your Green Home Improvement Loan.

Choose An Eligible Upgrade to Save More

Ready to invest in a greener future and dramatically lower your expenses? Our specialized Green Home Improvement Loans make it easy to upgrade your home with the latest climate-friendly solutions. Secure the financing you need to start seeing huge energy savings, slash your monthly utility bills, and move toward sustainable living. Explore our affordable financing options and start your project today!

Eligible Products and Services for Green Home Improvement Loans
Category
Eligible Products and Services
Requirements
Loan Type

Footnotes
(2) May be eligible for inclusion in a Secured loan if: (1) it is installed with a Secured product (including solar, geothermal, green home improvement, and auto loans); (2) it and all Unsecured products collectively comprise less than 50% of the loan amount.
Minimum/Maximum Loan Size, Unsecured Loans = $1,000 / $50,000
(3) For secured loans, a Uniform Commercial Code (UCC) form will be filed at both the State and County level.
Minimum/Maximum Loan Size, Secured Loans = $3,000 / $75,000
(4) Federal and local programs may have different eligibility requirements to receive rebates or tax credits. Please consult with a tax professional to ensure you are eligible for rebates and tax credits.
(5) Solar PV and BIPV projects must be installed by one of our Registered Dealers in order to be eligible for a secured loan.

Fire Mitigation Standards Reference: IBHS Wildfire Prepared Home (Base) addresses ember exposure; Wildfire Prepared Home Plus adds flame and radiant-heat protection. Structure and Zone 0 items are verifiable against the IBHS standard. Defensible space (5-100 ft) follows CA Public Resources Code 4291 and CAL FIRE guidance, covering former Zones 1 and 2. Zone 0 (0-5 ft ember-resistant zone) under AB 3074 is in state rulemaking, expected to finalize in 2026; insurers and some local jurisdictions (e.g., Berkeley) enforce equivalent requirements today.

ASTM E136 = noncombustible material test. ASTM E108 / UL 790 = roof fire-rating (Class A). ASTM E2886 = WUI vent flame/ember test. ASTM E119 / UL 263 = fire-resistance-rated assembly. NFPA 252 = fire door test.

Verification Tip: A “safety listing mark” means the product label or spec sheet shows one of these logos/phrases: “UL Listed,” “ETL Listed,” “CSA Certified,” or the ENERGY STAR® logo. These marks confirm the product has been independently tested for safety. If you cannot find a mark, ask the installer to provide the manufacturer’s spec sheet.

HVAC and appliance efficiency criteria (Central Air Conditioning; Air or Ground Source Heat Pump; Clothes Washer) updated July 2026 to reflect current ENERGY STAR Version 6.2 Central Air Conditioner and Heat Pump Specification (SEER2/EER2/HSPF2 metrics, effective since January 1, 2023) and current CEE clothes washer metrics (IMEF/IWF). Confirm CEE Tier 3 numeric thresholds against CEE’s live Residential Clothes Washer Qualifying Product List at cee1.org before underwriting, as CEE updates these periodically.

Category
ENERGY ANALYSIS & MONITORING
Eligible Products and Services
Energy Audit or Assessment
Requirements
Utility or Government Sponsored program.
Loan Type
Unsecured (2)(4)
Category
Eligible Products and Services
In-Home Monitor Equipment / Home Automation
Requirements
Cannot exceed $500 including install.
Loan Type
Unsecured (2)(4)
Category
Eligible Products and Services
Home Energy Rating Index (HERS Model)
Requirements
Performed by a RESNET certified Home Energy Rater.
Loan Type
Unsecured (2)(4)
Category
BUILDING ENVELOPE
Eligible Products and Services
Storm Windows and Doors
Requirements
ENERGY STAR®, Low-E Coating. Meets IECC in combination with the exterior window/door over which it is installed, for the applicable climate zone. On existing building shell only (no additions or new construction).
Loan Type
Secured (3)(4)
Category
Eligible Products and Services
Exterior Doors
Requirements
ENERGY STAR®, R-6.5 minimum fiberglass doors only with weather-stripping and threshold. Any glass must be double-paned, Low-E, and tempered.
Loan Type
Secured (3)(4)
Category
Eligible Products and Services
Air Sealing
Requirements
Air infiltration levels must be measured by a blower door before and after improvements. Mechanical ventilation must be recommended if air changes / hour are below 0.35 NACH. Performed to at least local code requirements.
Loan Type
Unsecured (2)
Category
Eligible Products and Services
Exterior Windows and Glass Doors
Requirements
ENERGY STAR®, U Value <= 0.30, Low-E glass. Garages and other non-living areas do not qualify unless they are part of the home’s conditioned space.
Loan Type
Secured (3)(4)
Category
Eligible Products and Services
Window Covers & Awnings
Requirements
Must consult with an energy advisor and refer to www.efficientwindowcoverings.org for a list of eligible brands and models.
Loan Type
Secured (3)(4)
Category
Eligible Products and Services
Solar Light Tube
Requirements
ENERGY STAR®, U-factor <= 0.55.
Loan Type
Secured (3)(4)
Category
Eligible Products and Services
Ceiling/Attic Insulation
Requirements
R-49 minimum required in open attic; cathedral ceilings will vary with rafter depth. Must perform air sealing in attics prior to adding insulation.
Loan Type
Secured (3)(4)
Category
Eligible Products and Services
Wall Insulation
Requirements
Compliant with International Energy Conservation Code, varies by climate zone. For framed walls R-19 minimum: fill wall cavity where R-19 is not possible. For solid walls such as brick or concrete, exterior rigid insulation must be added to a level of R-10 or higher.
Loan Type
Secured (3)(4)
Category
Eligible Products and Services
Foundation (Crawl Space or Basement) Insulation & Air Sealing
Requirements
Crawlspace as outlined in the 2012 IECC. R-15 continuous or R-19 cavity insulation with a vapor permeable air barrier over insulation. Crawlspaces must have sealed vapor barrier over dirt crawl space floor and ventilation, per 2012 IRC.
Loan Type
Secured (3)(4)
Category
Eligible Products and Services
Sub-Floor or Frame Floor Insulation
Requirements
R-30 minimum, over unconditioned space only (i.e., cantilevers, floors over unconditioned crawl, over garage, etc.). Fill enclosed floor cavities when R-30 is not possible. As per 2012 IECC.
Loan Type
Secured (3)(4)
Category
Eligible Products and Services
Perimeter Insulation, Slab-on-Grade Foundations
Requirements
R-10 minimum. Must extend to entire perimeter of any exposed slab(s), as per 2012 IECC.
Loan Type
Secured (3)(4)
Category
Eligible Products and Services
Cool/Reflective/PV Roof
Requirements
Cool Roof Rating Council rated roof materials with an Initial Solar Reflectance Index (SRI) of >= 75 for low-slope, >= 20 for steep-slope roofs; solar PV roof tiles; or ENERGY STAR rated roofing materials. Roofing requests must be reviewed by Clean Energy CU prior to approval. A list of rated materials can be found at coolroofs.org/directory/roof.
Loan Type
Unsecured (2)(4)
Category
HVAC
Eligible Products and Services
Whole Home or Attic Fan
Requirements
Fan must have an automated, insulated air sealing mechanism that engages when the fan is off (i.e., doors or damper mechanism, etc). Must have controls (thermostat or timer, multi-speed).
Loan Type
Secured (3)(4)
Category
Eligible Products and Services
Natural Gas or Propane Furnace
Requirements
ENERGY STAR®, AFUE >= 95%.
Loan Type
Secured (3)(4)
Category
Eligible Products and Services
Whole Home Humidifier
Requirements
ENERGY STAR®.
Loan Type
Secured (3)(4)
Category
Eligible Products and Services
Whole Home Dehumidifier
Requirements
ENERGY STAR®.
Loan Type
Secured (3)(4)
Category
Eligible Products and Services
Heat Recovery Ventilator (HRV)
Requirements
Must be reviewed by Clean Energy CU prior to approval.
Loan Type
Secured (3)(4)
Category
Eligible Products and Services
Energy Recovery Ventilator (ERV)
Requirements
Must be reviewed by Clean Energy CU prior to approval.
Loan Type
Secured (3)(4)
Category
Eligible Products and Services
Natural Gas or Propane Boiler
Requirements
ENERGY STAR®, AFUE >= 90%.
Loan Type
Secured (3)(4)
Category
Eligible Products and Services
Central Air Conditioning
Requirements
ENERGY STAR®. Current certification minimums: SEER2 >= 15.2 and EER2 >= 12.0 (split system); SEER2 >= 15.2 and EER2 >= 11.5 (single package). DOE retired the legacy SEER/EER metrics for new equipment effective January 1, 2023; all new units are tested and rated under SEER2/EER2.
Loan Type
Secured (3)(4)
Category
Eligible Products and Services
Evaporative Cooling, Whole Home
Requirements
85% media saturation. Must be permanently installed.
Loan Type
Secured (3)(4)
Category
Eligible Products and Services
Air or Ground Source Heat Pump (incl. Mini-Split Units)
Requirements
ENERGY STAR®. Current certification minimums (split system): SEER2 >= 15.2, EER2 >= 12.0, HSPF2 >= 8.1. Ground source: closed loop systems only, 6 tons or smaller. DOE retired the legacy SEER/HSPF metrics for new equipment effective January 1, 2023; all new units are tested and rated under SEER2/HSPF2.
Loan Type
Secured (3)(4)
Category
Eligible Products and Services
Pellet or Wood Stove/Boiler
Requirements
EPA Certified, at least 72% efficient (wood) or 78% efficient (pellet). Upgrades only, unless home uses electric heat.
Loan Type
Secured (3)(4)
Category
Eligible Products and Services
Biomass Heating System
Requirements
3 MMBTU/hour or smaller.
Loan Type
Secured (3)(4)
Category
Eligible Products and Services
High Efficiency Fireplace & Fireplace Inserts
Requirements
EPA Certified, at least 75% efficient. Retrofits only.
Loan Type
Unsecured (2)(4)
Category
Eligible Products and Services
Electric Thermal Storage (ETS)
Requirements
Room, Whole Home, and Water ETS eligible.
Loan Type
Unsecured (2)(4)
Category
Eligible Products and Services
Programmable Thermostat
Requirements
5-2 Day minimum.
Loan Type
Unsecured (2)(4)
Category
Eligible Products and Services
Smart Thermostat
Requirements
ENERGY STAR®.
Loan Type
Unsecured (2)(4)
Category
Eligible Products and Services
Room Air Conditioner
Requirements
ENERGY STAR®.
Loan Type
Unsecured (2)(4)
Category
Eligible Products and Services
Duct Sealing/Repair
Requirements
Duct replacement: seal to 10% or less for replacement ducts. Must use duct mastic, aluminized tape, or pressurized aerosol sealant. Performed to at least local code requirements.
Loan Type
Unsecured (2)(4)
Category
Eligible Products and Services
Duct Insulation
Requirements
R-8 minimum, in unconditioned space only. Compliant with International Energy Conservation Code, varies by climate zone.
Loan Type
Unsecured (2)(4)
Category
WATER HEATING
Eligible Products and Services
Hot Water Heater Gas/Propane Storage
Requirements
ENERGY STAR®, Tank min. rating EF >= 0.67.
Loan Type
Secured (3)(4)
Category
Eligible Products and Services
Hot Water Heater Electric/Gas/Propane Tankless
Requirements
ENERGY STAR®, EF >= 0.90.
Loan Type
Secured (3)(4)
Category
Eligible Products and Services
Heat Pump Water Heater (Integrated / Hybrid)
Requirements
Must carry the ENERGY STAR® label. Confirm ENERGY STAR certification by searching the model number at energystar.gov/productfinder. The product listing or spec sheet must show a Uniform Energy Factor (UEF) of 3.30 or higher. For 120-volt plug-in models, UEF of 2.80 or higher is acceptable. Must be installed by a licensed contractor.
Loan Type
Secured (3)(4)
Category
Eligible Products and Services
Heat Pump Water Heater (Split System)
Requirements
Must carry the ENERGY STAR® label. Confirm ENERGY STAR certification by searching the model number at energystar.gov/productfinder. The product listing or spec sheet must show a UEF of 2.80 or higher. Must be installed by a licensed contractor.
Loan Type
Secured (3)(4)
Category
LIGHTING, ELECTRICAL & SMART ENERGY MANAGEMENT
Eligible Products and Services
Lighting
Requirements
LED lighting and fixtures.
Loan Type
Unsecured (2)(4)
Category
Eligible Products and Services
Smart Electrical Panel (e.g., Span, Lumin)
Requirements
Must provide circuit-level energy monitoring and control via a mobile app. The product spec sheet or manufacturer’s website must show a safety listing mark (“UL Listed” or “ETL Listed”). Must be installed alongside or integrated with an existing solar PV, battery, or EV charging system. Installed by a licensed electrician.
Loan Type
Secured (3)(4)
Category
Eligible Products and Services
Home Energy Management System (HEMS)
Requirements
Must integrate with at least 2 home energy systems (e.g., HVAC, water heater, solar, storage, EV charger). Must include a mobile app for monitoring and control. Product must carry a safety listing mark (“UL Listed” or “ETL Listed”) on the spec sheet. Cannot exceed $5,000 including installation.
Loan Type
Unsecured (2)(4)
Category

ELECTRIC VEHICLE CHARGERS

Eligible Products and Services
Residential Electric Vehicle Supply Equipment (EVSE)
Requirements
Level 1 (120V), Level 2 (240V), or Level 3 (DC) electric vehicle charging equipment.
Loan Type
Secured (3)(4)
Category
Eligible Products and Services
Bidirectional EV Charger (Vehicle-to-Home / Vehicle-to-Grid)
Requirements
The product spec sheet or manufacturer’s website must confirm Vehicle-to-Home (V2H) or Vehicle-to-Grid (V2G) capability. Must carry a safety listing mark (“UL Listed” or “ETL Listed”) on the product label or spec sheet. Level 2 (240V) minimum. Must be compatible with the borrower’s electric vehicle (confirm on manufacturer’s compatibility list). Installed by a licensed electrician.
Loan Type
Secured (3)(4)
Category
RESIDENTIAL SOLAR, BATTERIES & ENERGY STORAGE
Eligible Products and Services
Solar Water Heating System (Active, Residential)
Requirements
The complete system must be certified under the ICC-SRCC OG-300 program. Confirm certification by searching the system model at solar-rating.org. The installer’s contract should reference the OG-300 certification number. Systems with the ENERGY STAR® label are preferred. If used for space heating, maximum size = 20 kW. Installation must be performed per the manufacturer’s specifications.
Loan Type
Secured (3)(4)
Category
Eligible Products and Services
Solar Water Heating System (Commercial / Pool)
Requirements
Solar collectors must be certified under the ICC-SRCC OG-100 program. Confirm certification by searching at solar-rating.org. Must be reviewed by Clean Energy CU prior to approval for commercial applications. Installed by a licensed contractor.
Loan Type
Secured (3)(4)
Category
Eligible Products and Services
Solar Photovoltaics (PV) / Solar Electricity
Requirements
We require that a solar PV project be installed by one of our Registered Dealers in order to be eligible for a secured loan.
Loan Type
Secured (4)(5)
Category
Eligible Products and Services
Solar Photovoltaics (PV) / Solar Electricity (Outside of Registered Dealer Program)
Requirements
For an unsecured loan, these types of projects may qualify: (1) “do-it-yourself” solar PV projects (i.e., self-installing the equipment or self-managing a project that includes multiple contractors under your supervision); (2) community solar garden subscriptions; and (3) solar PV roof tiles (which are not eligible for secured loans even if installed by a Registered Dealer).
Loan Type
Unsecured (2)(4)
Category
Eligible Products and Services
Solar Awnings / Canopies / Carports
Requirements
Solar panels must carry a safety listing mark (“UL Listed” or “ETL Listed”) on the spec sheet. The inverter must also carry a safety listing mark. A structural review or engineering stamp is required for the support structure (installer to provide). Local building permit required. Grid-tied systems require a signed utility interconnection agreement.
Loan Type
Secured (4)(5)
Category
Eligible Products and Services
Battery Systems
Requirements
Must be Grid Tied or PV System Tied and have a capacity rating of 3 kilowatt-hours (kWh) or greater and a minimum 10-year manufacturer’s warranty.
Loan Type
Secured (3)(4)
Category
Eligible Products and Services
Thermal Energy Storage (Ice or Phase-Change System)
Requirements
Must be paired with a heat pump HVAC system. The product spec sheet must show a safety listing mark (“UL Listed” or “ETL Listed”). Manufacturer must offer a minimum 5-year warranty (confirm on spec sheet or warranty document). Must be reviewed by Clean Energy CU prior to approval.
Loan Type
Secured (3)(4)
Category
SMALL WIND ENERGY
Eligible Products and Services
Small Wind Turbine (Residential, up to 20 kW)
Requirements
Turbine must appear on the certified turbines list at smallwindcertification.org. Confirm the model name/number on the installer’s contract matches a listing on that directory. Rated power output must be 20 kW or less as shown on the spec sheet. Installer must provide proof of local permits (building permit, zoning approval). For grid-connected systems, a signed interconnection agreement with the utility is required.
Loan Type
Secured (3)(4)
Category
Eligible Products and Services
Small Wind Turbine (Small Commercial, 20–100 kW)
Requirements
Same as residential: turbine model must appear on the certified turbines list at smallwindcertification.org. Rated power between 20 kW and 100 kW as shown on the spec sheet. Installer must provide a professional wind study showing the site is suitable. All local permits and utility interconnection agreement required.
Loan Type
Secured (3)(4)
Category
MICROHYDROPOWER
Eligible Products and Services
Microhydropower System (Residential, 2–100 kW)
Requirements
Turbine must be from a manufacturer that has been in business for at least 5 years and publishes product spec sheets with efficiency ratings. The spec sheet should show a safety certification mark (such as “UL Listed,” “CSA Certified,” or “ETL Listed”) on the generator and inverter. System size between 2 kW and 100 kW. Installer must provide: (1) a site assessment showing water flow and drop height, (2) all required federal, state, and local permits, and (3) a signed utility interconnection agreement for grid-connected systems. Refer to Microhydropower Loan Product Guideline for detailed underwriting criteria.
Loan Type
Secured (3)(4)
Category
Eligible Products and Services
Microhydropower System (Small Commercial, 2–300 kW)
Requirements
Same equipment requirements as residential. System size between 2 kW and 300 kW. An independent energy production estimate from a licensed Professional Engineer is required (not just the installer’s estimate). All federal, state, and local permits must be obtained or in progress before funding. Refer to Microhydropower Loan Product Guideline for detailed underwriting criteria.
Loan Type
Secured (3)(4)
Category
WATER EFFICIENCY & RECLAMATION
Eligible Products and Services
Rainwater Harvesting System
Requirements
Must comply with state and local regulations (installer must confirm in writing that the system is permitted in the borrower’s jurisdiction). Minimum 500-gallon storage capacity as shown on the installer’s contract. System must include filtration appropriate for intended use. Installed by a licensed contractor. Cannot exceed $25,000.
Loan Type
Secured (3)(4)
Category
Eligible Products and Services
Greywater Recycling System
Requirements
Installer must confirm in writing that the system complies with state and local plumbing codes. For indoor reuse: the treatment unit must be NSF 350 certified (confirm on the product label or manufacturer’s website at nsf.org). Local permit required. Installed by a licensed plumber.
Loan Type
Secured (3)(4)
Category
Eligible Products and Services
Solar Water Purification / UV Treatment
Requirements
Treatment unit must be NSF 55 certified (confirm Class A or Class B designation on the product label or at nsf.org). Must serve borrower’s primary residence or commercial facility. Cannot exceed $10,000 including installation.
Loan Type
Unsecured (2)(4)
Category
POOL PRODUCTS
Eligible Products and Services
Pool Pumps
Requirements
ENERGY STAR®.
Loan Type
Secured (3)(4)
Category
APPLIANCES
Eligible Products and Services
Dishwasher
Requirements
ENERGY STAR®. Recommend CEE Tier 1 (<= 270 kWh/yr & <= 3.5 gal/cycle).
Loan Type
Secured (3)(4)
Category
Eligible Products and Services
Clothes Washer
Requirements
ENERGY STAR®. Recommend CEE Tier 3, measured using CEE’s current metrics: Integrated Modified Energy Factor (IMEF) and Integrated Water Factor (IWF), which replaced the older Modified Energy Factor (MEF) / Water Factor (WF) metrics. CEE updates qualifying tier thresholds periodically; confirm the current Tier 3 IMEF/IWF minimums against CEE’s Residential Clothes Washer Qualifying Product List (cee1.org) at time of underwriting.
Loan Type
Secured (3)(4)
Category
Eligible Products and Services
Induction Stove or Cooktop
Requirements
ENERGY STAR®.
Loan Type
Secured (3)(4)
Category
Eligible Products and Services
Clothes Dryer (Standard)
Requirements
ENERGY STAR®.
Loan Type
Secured (3)(4)
Category
Eligible Products and Services
Clothes Dryer (Heat Pump Technology)
Requirements
Must carry the ENERGY STAR® label. Confirm by searching the model number at energystar.gov/productfinder. The product description must state “heat pump” technology (not standard electric resistance).
Loan Type
Secured (3)(4)
Category
Eligible Products and Services
Refrigerator (Larger than 10 Cubic Feet)
Requirements
ENERGY STAR®.
Loan Type
Secured (3)(4)
Category
Eligible Products and Services
Freezer (Larger than 10 Cubic Feet)
Requirements
ENERGY STAR®.
Loan Type
Secured (3)(4)
Category
Eligible Products and Services
Air Cleaner/Purifier
Requirements
ENERGY STAR®.
Loan Type
Unsecured (2)(4)
Category
Eligible Products and Services
Ceiling Fan
Requirements
ENERGY STAR®.
Loan Type
Unsecured (2)(4)
Category
ELECTRIFICATION & FUEL SWITCHING
Eligible Products and Services
Whole-Home Electrification Package
Requirements
A bundled loan covering the conversion of 2 or more systems from fossil fuel to electric (e.g., HVAC heat pump + heat pump water heater + induction range). Each individual product in the package must meet the requirements listed for that product on this list. The installer’s contract must itemize each product separately with manufacturer and model number. An energy audit or HERS assessment is recommended but not required.
Loan Type
Secured (3)(4)
Category
FIRE MITIGATION – STRUCTURE HARDENING (IBHS Wildfire Prepared Home)
Eligible Products and Services
Class A Fire-Rated Roof Covering or Assembly; Metal Valley Flashing; Fire-Resistant / Synthetic Underlayment
Requirements
Class A rated (ASTM E108 or UL 790). Metal flashing at valleys and roof edges; fire-resistant underlayment.
Loan Type
Unsecured (2)(4)
Category
Eligible Products and Services
WUI Ember- and Flame-Resistant Vents, or Screen-Covered Vents (Eave, Gable, Foundation, Under-Floor)
Requirements
ASTM E2886, or vent openings covered with noncombustible, non-corrosive 1/16-inch mesh (ASTM E136). Applies to all exterior vents.
Loan Type
Unsecured (2)(4)
Category
Eligible Products and Services
Noncombustible (Metal) Gutters, Downspouts, and Gutter Covers
Requirements
Noncombustible (ASTM E136). Noncombustible gutter cover required to meet WPH Plus.
Loan Type
Unsecured (2)(4)
Category
Eligible Products and Services
Enclosed Eaves with Noncombustible Soffit
Requirements
Noncombustible (ASTM E136), or assembly rated to ASTM E119 / UL 263. WPH Plus measure.
Loan Type
Unsecured (2)(4)
Category
Eligible Products and Services
Noncombustible Siding and Trim
Requirements
Noncombustible (ASTM E136). WPH Base: minimum 6 inches noncombustible at base of wall. WPH Plus: full noncombustible covering.
Loan Type
Secured (3)(4)
Category
Eligible Products and Services
Dual-Pane Tempered Windows and Skylights, or Fire-Rated Glazing
Requirements
Dual-pane with at least 1 tempered pane (CWUIC Part 7) or 2 tempered panes (WPH Plus); safety glazing (ANSI Z97.1 or CPSC 16 CFR 1201); or 20-minute fire-rated.
Loan Type
Secured (3)(4)
Category
Eligible Products and Services
Noncombustible, Fire-Rated, or Solid-Core Exterior Doors
Requirements
Noncombustible (ASTM E136); 20-minute fire-rated (NFPA 252); or solid core not less than 1-3/4 inches. WPH Plus measure.
Loan Type
Secured (3)(4)
Category
Eligible Products and Services
Noncombustible Decks, Porches, and Stairs; Metal Mesh Under-Deck Screening
Requirements
Noncombustible (ASTM E136), or assembly rated to ASTM E119 / UL 263. Enclose under-deck area to prevent debris accumulation.
Loan Type
Secured (3)(4)
Category
FIRE MITIGATION – NEAR-HOME ZONE 0 (0–5 FT Ember-Resistant Zone)
Eligible Products and Services
Noncombustible Ground Cover Within 0–5 ft (Rock, Gravel, Decomposed Granite, Pavers, Hardscape) Replacing Bark/Wood Mulch and Vegetation
Requirements
Noncombustible ground surface within 5 ft of structure and attached deck. No combustible mulch or plantings in this zone.
Loan Type
Unsecured (2)(4)
Category
Eligible Products and Services
Noncombustible Fencing and Gates Within 5 ft of the Structure
Requirements
Noncombustible (ASTM E136).
Loan Type
Secured (3)(4)
Category
Eligible Products and Services
Removal of Combustible Structures, Stored Materials, and Vegetation Within 5 ft; Conversion to a Noncombustible Surface
Requirements
Per AB 3074 / Zone 0. State rulemaking finalizing in 2026; insurers and LA County enforcing equivalent requirements today.
Loan Type
Unsecured (2)(4)
Category
FIRE MITIGATION – DEFENSIBLE SPACE (5–100 FT, CA PRC 4291)
Eligible Products and Services
Tree Trimming and Removal: Limbing, Pruning, Canopy Spacing, and Hazard Tree Removal
Requirements
CA PRC 4291 / CAL FIRE (Zones 1-2). Remove branches within 6 ft of ground (or 1/3 tree height for small trees); maintain 10 ft canopy spacing; clear limbs within 10 ft of chimney and overhanging the roof; remove dead, dying, or diseased trees. Spacing increases on slopes.
Loan Type
Unsecured (2)(4)
Category
Eligible Products and Services
Vegetation Maintenance and Clearing: Brush, Shrubs, Grass, and Surface Fuels
Requirements
CA PRC 4291 / CAL FIRE (Zones 1-2). Remove dead/dying plants, leaves, needles, and debris; mow annual grasses to 4 inches max; space shrubs to break continuous fuel and remove ladder fuels; remove surface litter (permitted to 3-inch depth); keep 10 ft clearance around wood piles, outbuildings, and propane tanks; relocate combustible storage.
Loan Type
Unsecured (2)(4)
Category
WIND/HAIL MITIGATION
FORTIFIED ROOF
(IBHS 2025 FORTIFIED Home Standard)
Eligible Products and Services
Wind-rated, Class 4 impact-rated roof covering: asphalt/fiberglass shingle, metal, or tile
Requirements
Wind rating per ASTM D3161 Class F or D7158 Class H (shingles) or equivalent for metal/tile; UL 2218 Class 4 impact rating for hail. Installed per manufacturer high-wind specifications.
Loan Type
Unsecured (2)(4)
Category
Eligible Products and Services
Enhanced roof deck re-nailing: ring-shank nails at tightened spacing
Requirements
8d ring-shank nails at 6 in. edge / 6 in. field, or equivalent mean ultimate uplift resistance of at least 182 psf. Required for all 2025 FORTIFIED Roof designations.
Loan Type
Unsecured (2)(4)
Category
Eligible Products and Services
Sealed roof deck / secondary water resistance (SWR)
Requirements
Fully adhered polymer-modified bitumen underlayment (ASTM D1970); or taped deck seams (min 3.75 in. ASTM D1970 strip or AAMA 711 Level 3 flashing tape) with felt or synthetic; or two layers ASTM D226 Type II / D4869 Type III-IV / D8257. Standard underlayment or hot-mopped felt does not qualify.
Loan Type
Unsecured (2)(4)
Category
Eligible Products and Services
Locked-down roof edges: enhanced metal drip edge and edge flashing
Requirements
Wider-face drip edge fastened at enhanced spacing per the FORTIFIED Roof detail set; fully adhered starter strips at eaves and rakes.
Loan Type
Unsecured (2)(4)
Category
Eligible Products and Services
Wind- and rain-rated roof vents; gable end vent protection
Requirements
Roof-mounted vents tested to resist wind-driven rain entry (TAS 100(A)); required under the 2025 FORTIFIED standard.
Loan Type
Unsecured (2)(4)
Category
WIND/HAIL MITIGATION
FORTIFIED SILVER
(openings and attached structures)
Eligible Products and Services
Impact-resistant windows, entry doors, sliding glass doors, and skylights, or code-approved protective coverings (shutters, panels)
Requirements
Cyclic pressure and large-missile impact: Miami-Dade PA / TAS 201, 202, 203; ASTM E1886 / E1996; or SSTD 12. 9-lb missile is the strongest credit tier.
Loan Type
Secured (3)(4)
Category
Eligible Products and Services
Wind-pressure-rated and impact-rated garage doors
Requirements
ANSI/DASMA 115 (impact) or ASTM E330 / ANSI/DASMA 108 / PA-TAS 202 (pressure). Credits are scored on the weakest opening: one unrated garage door forfeits the opening-protection differential.
Loan Type
Secured (3)(4)
Category
Eligible Products and Services
Gable end bracing and reinforcement
Requirements
Gable ends braced per FORTIFIED Silver requirements to resist lateral wind loads.
Loan Type
Unsecured (2)(4)
Category
Eligible Products and Services
Anchoring of attached structures: porches, carports, elevated decks
Requirements
Connections sized to FORTIFIED uplift requirements (prescriptive calculator or engineered design).
Loan Type
Unsecured (2)(4)
Category
Eligible Products and Services
Chimney reinforcement and anchorage
Requirements
Chimneys anchored and braced per FORTIFIED Silver.
Loan Type
Unsecured (2)(4)
Category
WIND/HAIL MITIGATION
FORTIFIED GOLD
(continuous load path)
Eligible Products and Services
Roof-to-wall connection retrofit: hurricane clips, single-wrap or double-wrap straps
Requirements
Purpose-made connectors installed per manufacturer specification, with substantiated wind allowable uplift capacity: clips 386 lbs or greater; single wraps 535 lbs or greater; double wraps 891 lbs or greater (site-specific documentation required).
Loan Type
Unsecured (2)(4)
Category
Eligible Products and Services
Wall-to-wall and wall-to-foundation anchorage; continuous load path tie-in
Requirements
Connectors and anchors forming a continuous load path from roof to foundation per FORTIFIED Gold (engineered or prescriptive).
Loan Type
Unsecured (2)(4)

Finance your Next Home Improvement Project with Us!